A new version of the firmware for the dBadge has been released to further improve the use of the new noise dosimeter.

The new firmware version 1.05 adds a new parameter to the displayed set of results shown on the screen of the dBadge  at the end of measurements. The new parameter is the 8 hour projected noise dose based on the actual noise dose % collected during the run. For example, if the  had been running for a sample period of 2 hours (120 minutes) and accumulated an actual noise dose of 37% then the 8 hour projected dose would be shown as 480/120 x 37% or 148%.

This new benefit allows for shorter measurements to be made when the noise exposure is pretty consistent all through the workday. If the projected dose is known then the TWA can be calculated easily from the following relationship.

TWA = 16.61 x log (8hr proj dose%/100%) + 90 dB

In the example above the TWA will be 92.6 dB.

Just to round off the upgrade the new version 1.05 for the dBadge also adds the capability of selecting the display screen menus in Portuguese language in addition to English, Spanish, French, Italian and German.

Click here to download the zipped file to upgrade your own dBadges too. Save the file in a temp folder on your hard drive then unzip the 2 files and follow the instructions given in the text file UPGHELP.TXT.

 

Home | What's New | Products available | F.A.Q. | After Sales Support | Suggestions | Datasheets / Manuals | Downloads

Questions or problems regarding this web site should be directed to webmaster@casellausa.com.
For general inquiries or pricing information please contact info@casellausa.com
Copyright © 2006 - 2007 Casella USA. All rights reserved.
Last modified: Thursday July 03, 2008.